Bulletin F-2 |
|
|
|
|
General
Description: |
|
Ordering Instructions: |
* Specify primary conduit opening |
|
* Fixture Type
Transformer |
|
* Order by model number shown |
desired 1
1/4 NPT or 1 1/2 NPT |
|
* Staggered
Secondary Lugs |
|
* Add "X" to model number if |
* Specify tap switch position on |
|
* Frame Cross
Section 7 1/4" X 9 1/4 " |
transformer is to be fully potted |
5-way
mount models |
|
|
Wound Core |
|
KVA Rating |
Secondary |
Tap Switch |
Primary |
Model Number |
Weight |
Dwg. |
Frame |
Turns Ratio (xx:1 Unless in Series Then xx:2) 440 Volt |
110 C Rise |
Voltage Range |
Location |
Connection |
220V/60 Hz |
440V/60 Hz |
Approx. |
No. |
Letter |
Tap 1 |
Tap 2 |
Tap 3 |
Tap 4 |
|
3.2 to 5.0 |
End Mount |
Disconnect Plug |
F22660A1ABW |
F44660A1ABW |
137 |
R1288 |
|
|
|
|
|
60 |
Volts |
|
Solderless Lug |
F22660A1BBW |
F44660A1BBW |
|
|
A |
138 |
116 |
100 |
88 |
|
4 Steps |
5 Way Mount |
Disconnect Plug |
F22660A1CBW |
F44660A1CBW |
142 |
R1299 |
|
|
|
|
|
|
|
|
Solderless Lug |
F22660A1DBW |
F44660A1DBW |
|
|
|
|
|
|
|
|
4.0 to 6.0 |
End Mount |
Disconnect Plug |
F22670E1ABW |
F44670E1ABW |
152 |
R1288 |
|
|
|
|
|
70 |
Volts |
|
Solderless Lug |
F22670E1BBW |
F44670E1BBW |
|
|
E |
105 |
92 |
82 |
74 |
|
4 Steps |
5 Way Mount |
Disconnect Plug |
F22670E1CBW |
F44670E1CBW |
158 |
R1299 |
|
|
|
|
|
|
|
|
Solderless Lug |
F22670E1DBW |
F44670E1DBW |
|
|
|
|
|
|
|
|
5.2 to 7.1 |
End Mount |
Disconnect Plug |
F22685B1ABW |
F44685B1ABW |
173 |
R1288 |
|
|
|
|
|
85 |
Volts |
|
Solderless Lug |
F22685B1BBW |
F44685B1BBW |
|
|
B |
85 |
76 |
68 |
62 |
|
4 Steps |
5 Way Mount |
Disconnect Plug |
F22685B1CBW |
F44685B1CBW |
178 |
R1299 |
|
|
|
|
|
|
|
|
Solderless Lug |
F22685B1DBW |
F44685B1DBW |
|
|
|
|
|
|
|
|
6.9 to 9.0 |
End Mount |
Disconnect Plug |
|
F446120J1ABW |
200 |
R1288 |
|
|
|
|
|
120 |
Volts |
|
Solderless Lug |
F226120J1BBW |
F446120J1BBW |
|
|
J |
64 |
59 |
54 |
49 |
|
4 Steps |
5 Way Mount |
Disconnect Plug |
|
F446120J1CBW |
205 |
R1299 |
|
|
|
|
|
|
|
|
Solderless Lug |
F226120J1DBW |
F446120J1DBW |
|
|
|
|
|
|
|
|
9.4 to 11.5 |
End Mount |
Disconnect Plug |
|
F446150JL1ABW |
236 |
R1288 |
|
|
|
|
|
150 |
Volts |
|
Solderless Lug |
F226150JL1BBW |
F446150JL1BBW |
|
|
JL |
47 |
44 |
41 |
38 |
|
4 Steps |
5 Way Mount |
Disconnect Plug |
|
F446150JL1CBW |
241 |
R1299 |
|
|
|
|
|
|
|
|
Solderless Lug |
F226150JL1DBW |
F446150JL1DBW |
|
|
|
|
|
|
|
|
Stacked Core |
|
KVA Rating |
Secondary |
Tap Switch |
Primary |
Model Number |
Weight |
Dwg. |
Frame |
Turns Ratio (xx:1 Unless in Series Then xx:2) 440 Volt |
110 C Rise |
Voltage Range |
Location |
Connection |
220V/60 Hz |
440V/60 Hz |
Approx. |
No. |
Letter |
Tap 1 |
Tap 2 |
Tap 3 |
Tap 4 |
|
2.4 to 3.5 |
End Mount |
Disconnect Plug |
F22635A1ABL |
F44635A1ABL |
143 |
R1288 |
|
|
|
|
|
35 |
Volts |
|
Solderless Lug |
F22635A1BBL |
F44635A1BBL |
|
|
A |
170 |
154 |
140 |
126 |
|
4 Steps |
5 Way Mount |
Disconnect Plug |
F22635A1CBL |
F44635A1CBL |
148 |
R1299 |
|
|
|
|
|
|
|
|
Solderless Lug |
F22635A1DBL |
F44635A1DBL |
|
|
|
|
|
|
|
|
2.9 to 4.2 |
End Mount |
Disconnect Plug |
F22645E1ABL |
F44645E1ABL |
165 |
R1288 |
|
|
|
|
|
45 |
Volts |
|
Solderless Lug |
F22645E1BBL |
F44645E1BBL |
|
|
E |
148 |
132 |
116 |
104 |
|
4 Steps |
5 Way Mount |
Disconnect Plug |
F22645E1CBL |
F44645E1CBL |
170 |
R1299 |
|
|
|
|
|
|
|
|
Solderless Lug |
F22645E1DBL |
F44645E1DBL |
|
|
|
|
|
|
|
|
3.2 to 5.2 |
End Mount |
Disconnect Plug |
F22655B1ABL |
F44655B1ABL |
182 |
R1288 |
|
|
|
|
|
55 |
Volts |
|
Solderless Lug |
F22655B1BBL |
F44655B1BBL |
|
|
B |
138 |
110 |
94 |
84 |
|
4 Steps |
5 Way Mount |
Disconnect Plug |
F22655B1CBL |
F44655B1CBL |
187 |
R1299 |
|
|
|
|
|
|
|
|
Solderless Lug |
F22655B1DBL |
F44655B1DBL |
|
|
|
|
|
|
|
|
4.5 to 6.5 |
End Mount |
Disconnect Plug |
F22665J1ABL |
F44665J1ABL |
225 |
R1288 |
|
|
|
|
|
65 |
Volts |
|
Solderless Lug |
F22665J1BBL |
F44665J1BBL |
|
|
J |
97 |
85 |
75 |
68 |
|
4 Steps |
5 Way Mount |
Disconnect Plug |
F22665J1CBL |
F44665J1CBL |
230 |
R1299 |
|
|
|
|
|
|
|
|
Solderless Lug |
F22665J1DBL |
F44665J1DBL |
|
|
|
|
|
|
|
|
6.0 to 8.5 |
End Mount |
Disconnect Plug |
F22690JL1ABL |
F44690JL1ABL |
264 |
R1288 |
|
|
|
|
|
90 |
Volts |
|
Solderless Lug |
F22690JL1BBL |
F44690JL1BBL |
|
|
JL |
73 |
65 |
58 |
52 |
|
4 Steps |
5 Way Mount |
Disconnect Plug |
F22690JL1CBL |
F44690JL1CBL |
269 |
R1299 |
|
|
|
|
|
|
|
|
Solderless Lug |
F22690JL1DBL |
F44690JL1DBL |
|
|
|
|
|
|
|
|
Standard Features: |
|
* Blade type plug if applicable |
Optional Features: |
|
* Class
"F" insulation |
|
* Interchangeable with other |
* Voltages and frequencies other than |
|
* Totally enclosed
tap switch |
|
manufacturers |
|
shown
available on request |
|
* Secondary end
positively sealed |
|
* Thermostats |
|
against contamination |
|
|
|