Bulletin F-5
General Description: Ordering Instructions:
* Fixture Type Transformer * Order by model number shown
* Single Secondary * Add "X" to model number if
* Universal Tap Switch transformer is to be fully potted
* Frame Cross Section 5 3/4" X 9 1/4 "
Wound Core
KVA Rating Secondary Number Tap Switch Model Number Weight Dwg. Frame Turns Ratio for 460 Volt
110 C Rise Voltage Range Of Taps Location 230V/60 Hz 460V/60 Hz Approx. No. Letter Tap 1 Tap 2 Tap 3 Tap 4
                         
25 3.6 to 5.0 4 Universal F23625AS1GDW F46625AS1GDW 103 R1088 AS 126:1 114:1 102:1 92:1
                         
                         
35 4.6 to 6.0 4 Universal F23635ES1GDW F46635ES1GDW 114 R1088 ES 100:1 92:1 84:1 77:1
                         
                         
45 5.5 to 7.0 4 Universal F23645BS1GDW F46645BS1GDW 138 R1088 BS 84:1 78:1 72:1 65:1
                         
                         
65 7.2 to 9.0 4 Universal F23665JS1GDW F46665JS1GDW 165 R1088 JS 64:1 59:1 55:1 51:1
                         
                         
80 9.2 to 11.5 4 Universal F23680DS1GDWX F46680DS1GDWX 206 R1088 DS 50:1 46:1 43:1 40:1
        Fully Potted Only Fully Potted Only              
Standard Features: Optional Features:
* Class "F" insulation * Solderless lug connections * Voltages and frequencies other than
* Totally enclosed tap switch for primary wiring shown available on request
* Secondary end positively sealed * Thermostats
against contamination * Stacked core available on request